Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Recent Advances in Ophthalmology ; (6): 732-735, 2017.
Article in Chinese | WPRIM | ID: wpr-609882

ABSTRACT

Objective To analyze the thickness of cornea and corneal epithelium in healthy subjects by optical coherence tomography angiography (OCTA).Methods Totally 100 healthy subjects aged between 20 and 30 years were analyzed by OCTA technique.Using AngioVue OCTA system of retinal imaging mode,and using SSADA algorithm for imaging,the cornea and the corneal epithelium in the central corneal diameter range of 9 mm were measured.The differences of corneal and corneal epithelial thickness in different gender regions were compared.Results In the male and female group,the corneal central total thickness were (559.92 ±33.26) μm and(540.06 ±31.63)μm,and the corneal epithelial thickness were(57.78 ±4.88) μm and(56.88 ±4.57) μm,The total central corneal thickness and central corneal epithelial thickness of the male were greater than those of the female,the difference was statistically significant (t =3.06,2.10;all P < 0.05).The cornea of male was the thickest at S5,S7 and SN9,there were significant differences at S5 and S7 compared with female (t =2.93,2.83;all P < 0.05);The female cornea was the thickest at S5,SN7 and SN9,and the difference was significant at S5 compared with male.The cornea of male subjects was the thinnest at IT,which was statistically significant only at IT5 compared with female subjects in the same area (t =2.02,P < 0.05);The cornea of female subjects was the thinnest at T5,IT7 and T9,which was statistically significant only at T5 and T9 compared with male subjects in the same region (t =2.63,2.20;all P < 0.05);There was significant difference in corneal thickness between male and female at ST (t =3.1 1,2.79,2.33;all P < 0.05).The corneal epithelium was the thickest at IT5,I7,and I9,and the lowest at S5,S7 and S9,and there was no significant difference compared with female in the same region (all P > 0.05).The corneal epithelium of female at the IT5,T7,N9 were the thickest,SN5,S7,S9 were the thinnest;Except for M2 and SN5,there was no significant differences in corneal epithelium between male and female groups (all P > 0.05).Corneal central epithelium accounted for the largest percentage of total corneal thickness,and gradually decreased from inside to outside.Conclusion OCTA can be used to measure the thickness of corneal and corneal epithelial regions.

2.
Recent Advances in Ophthalmology ; (6): 788-792, 2017.
Article in Chinese | WPRIM | ID: wpr-609872

ABSTRACT

Accurate qualitative and quantitative assessment of anterior or posterior segment structures is crucial,not only for proper diagnosis of different ocular diseases but also for optimal surgical planning and postoperative follow-up.As a noninvasive and noncontact method,optical coherence tomography (OCT) has become an essential tests for the diagnosis of retinal diseases.To a more recent technology,swept-source OCT (SS-OCT) improved the depth of imaging and the scan speed,which can perform anterior segment evaluation liking corneal graft examination.Meanwhile,this newly technology add multimodal approach such as EVV,OCTA and En face OCT,for angiography and choroid mapping.Thus,SS-OCT has become a valuable imaging strategy to understand the pathologies of retinal diseases such as PVD,diabetic maculopathy,neovascularization and macular telangiectasia.With the use of multimodal approach,SS-OCT is beneficial for optimal surgical planning and postoperative follow-up for the vitreoretinal diseases,such as epiretinal membrane,retinal detachment,and diabetic taction retinal detachment.Moreover,this technology can help us better understand the ophthalmic pathologies of glaucoma and tumors.This article reviews the technical principles of SS-OCT and the advances in clinical applications.

3.
Recent Advances in Ophthalmology ; (6): 406-410, 2017.
Article in Chinese | WPRIM | ID: wpr-609802

ABSTRACT

Objective To explore prevention and cure effects of the freeze-dried human fibrin glue as the way of the lacrimal duct embolization on xerophthalmia in perimenopausal female rabbit.Methods A total of 72 female rabbits,after anti infection treatment and were cut off third eyelid,were made into perimenopausal xerophthalmia rabbit models.After surgery,all of these rabbits were randomly divided into 6 groups (12 rabbits per group):No treatment group after surgery (group A),PBS prevention group (group B),freeze-dried human fibrin prevention group (group C);no treatment group after modeling (modeling time:Two weeks after surgery,group D),PBS treatment group (group E),freeze-dried human fibrin treatmentgroup (group F).The Schirmer test (SIT),corneal fluorescein (FL) and corneal confocal microscope were performed before and 2 weeks,4 weeks,6 weeks after injection.Results There were statistical differences in FL score and SIT in group A,group B and group C among different time points (F =27.346,10.608;P =0.000,0.001);There were statistical differences between FL scores and SIT among three groups (F =7.579,6.786;P =0.002,0.007);There was significant difference in FL scores and SIT trends among three groups(F =44.897,3.424;P =0.000,0.045).The FL score and SIT of group D,group E and group F were significantly improved after treatment for 2 weeks,4 weeks and 6 weeks,the differences were statistically significant (t =2.906,3.654,4.504;P =0.022,0.017,0.013.t =4.573,5.759,7.231;P =0.032,0.019,0.008);The difference between FL score and SIT in group E and group F was statistically significant after treatment (t =2.776,4.124,5.324;P =0.032,0.026,0.017.t =1.969,3.122,4.324;P =0.038,0.023,0.009).After injection of 6 weeks,the epithelial basal cells (F =17.306,P =0.002) and inflammatory cells (F =34.024,P =0.000) of group A,B and C were significant changed,the differences were statistically significant.After injection of 6 weeks,the epithelial basal cells (F =3.749,P =0.042)and inflarnmatory cells(F=8.806,P =0.005) of group D,E and F were significant changed,the differences were also statistically significant.Conclusion Lacrimal duct embolization with freeze-dried human fibrin glue is effective for the xerophthalmia.

SELECTION OF CITATIONS
SEARCH DETAIL